Skip to content
FREE Shipping on Orders £90+ | Order before 3pm for next day delivery
Order before 3pm for next day delivery

BLAYDS PRODUCTS · CABLE GLANDS UK

RetroSeal®Split cable gland
IP washers

Replace a missing or damaged entry washer.
Keep the existing cable termination.

The two-part RetroSeal washer fits around an existing cable gland to renew the seal between the gland and enclosure, without disconnecting and re-terminating the cable.

TWO PARTS. ONE COMPLETE WASHER.
RetroSeal product logo
Retro-fit design · M20–M63
IP66 / IP67 Independently tested; fitting conditions apply
No re-termination Designed for existing cable gland installations
6 metric sizes M20, M25, M32, M40, M50 and M63

REPAIR THE ENTRY SEAL

A practical fix for an
existing installation.

A conventional one-piece washer can be difficult to replace once a cable has been terminated. RetroSeal opens into two parts, so it can be fitted at the gland-to-enclosure interface.

The gland is loosened to create the fitting gap, the two washer sections are joined around the entry thread, and the gland is reassembled in accordance with the manufacturer’s instructions.

This approach can reduce the work involved in replacing a worn, damaged or missing IP washer, particularly where disconnecting wiring would make a straightforward repair more disruptive.

01

Keep the cable terminated

The divided washer can be fitted around the existing entry thread, avoiding cable disconnection for the washer replacement.

02

Reduce maintenance work

Retain a serviceable gland and reduce the dismantling, materials and labour associated with replacing a conventional washer.

03

Renew the entry seal

Interlocking PA6 nylon sections form a complete washer at the equipment-to-gland interface.

SELECT BY GLAND ENTRY THREAD

Find the right RetroSeal.

Match the washer to the gland’s entry thread size.
Pack quantities vary by size.

RetroSeal metric sizes, manufacturer part codes and pack quantities
Entry thread size Manufacturer part code Washers per pack Enquire by size
M20 RETROSEAL-M20 10 Enquire about M20
M25 RETROSEAL-M25 10 Enquire about M25
M32 RETROSEAL-M32 10 Enquire about M32
M40 RETROSEAL-M40 5 Enquire about M40
M50 RETROSEAL-M50 5 Enquire about M50
M63 RETROSEAL-M63 5 Enquire about M63

M20–M63 identifies the gland’s metric entry thread, rather than cable diameter. Ask us to confirm suitability, pricing and availability for your installation.

PRODUCT SPECIFICATION

Technical information.

Manufacturer information for the RetroSeal two-part cable gland IP washer.

Open manufacturer datasheet
RetroSeal technical specifications
Product typeTwo-part retro-fit cable gland IP washer
Sealing positionBetween the cable gland and equipment or enclosure
MaterialPA6 nylon
Thickness3 mm
Environmental resistanceUV-resistant construction; manufacturer also describes ozone resistance
Ingress protectionManufacturer reports independent IP66/IP67 testing to IEC 60529. Installation sheet states IP66 without sealant and IPX7 with sealant.
Available thread sizesM20, M25, M32, M40, M50 and M63
Operating temperatureConfirm the applicable range with Cable Glands UK before specification.
Check the required installation conditions.

The manufacturer’s datasheet and installation sheet give different temperature ranges. Obtain confirmation for your application. For IP67 duty, follow the manufacturer’s specified sealing method and confirm the required compound.

HOW THE TWO-PART DESIGN FITS

Retro-fit, step by step.

Installation instructions

Installation must be carried out by qualified personnel. Follow site isolation procedures, the gland manufacturer’s instructions and all applicable requirements, including those for hazardous areas.

  1. Release the gland components

    Loosen the backnut and, where applicable, the middle nut to avoid twisting the cable or damaging the braid.

  2. Create the fitting gap

    Unscrew the gland from the enclosure by at least 5 mm. A clearance-hole entry secured by a locknut requires safe access inside the enclosure.

  3. Clean the sealing faces

    Clean the mating faces of the gland and equipment before fitting the replacement washer.

  4. Apply the specified compound

    The installation sheet calls for a small amount of electrical insulating compound on all four split ends and on the front and rear washer faces.

  5. Join the washer sections

    Place both halves around the entry thread and click them together. The joint is designed to assemble in one orientation.

  6. Refit the gland

    Secure the gland into the threaded entry or with the internal locknut, as appropriate for the enclosure.

  7. Reassemble and check

    Reassemble the remaining gland components to the gland manufacturer’s instructions and specified torque, then complete the required inspection.

This overview supports selection; use the full manufacturer’s instructions for the installation. RetroSeal’s IP test claim does not establish hazardous-area certification for a complete gland and enclosure assembly.

DOCUMENTS FOR YOUR PROJECT

Technical downloads.

Original documents from Blayds.
PDFs open in a new tab.

BEFORE YOU SPECIFY

Your questions,
answered.

Need help checking an existing gland?
Call 0161 874 1480

What is a RetroSeal split IP washer?

RetroSeal is a two-part PA6 nylon washer for the seal between a cable gland and an enclosure. It allows a missing, worn or damaged entry washer to be replaced around an existing gland installation.

Do I need to disconnect the cable?

The split design is intended to avoid disconnecting and re-terminating the cable. The gland still needs to be loosened and partly disassembled. Safe access inside the enclosure may also be needed, depending on the entry arrangement.

Is RetroSeal rated IP66 and IP67?

Blayds reports independent IP66/IP67 testing. Its installation sheet specifies IP66 without sealant and IPX7 with sealant. Follow the required installation method and confirm the compound for the protection level your application needs.

Which sizes and pack quantities are available?

M20, M25 and M32 are listed in packs of 10 washers. M40, M50 and M63 are listed in packs of 5. Select by the gland entry thread size, rather than the cable diameter.

Can I use it on a hazardous-area installation?

Have a qualified person assess the complete gland and equipment assembly against its certification, manufacturer’s instructions and site requirements. An IP rating alone does not confirm that an accessory is suitable for every hazardous-area installation.

How do I check price and availability?

Send Cable Glands UK the required thread size, number of packs and details of your installation using the form below, or call 0161 874 1480.

SPEAK TO CABLE GLANDS UK

Tell us what
you need to seal.

Send your RetroSeal size, pack quantity and application details. We’ll help you check the right option and confirm pricing and availability.

0161 874 1480

Supporting cable gland selection and maintenance enquiries from Trafford Park, Manchester.

RetroSeal enquiry

Fields marked * are required.

We’ll use these details to respond to your enquiry. Privacy policy.

RetroSeal® is a Blayds product. Manufacturer documents should be checked for the latest application and installation requirements.

PLAN YOUR MAINTENANCE COSTS

RetroSeal cost savings calculator

Compare replacing a conventional cable gland entry washer with fitting a RetroSeal split washer around an existing termination. Enter your project figures to estimate the difference.

Your project

The starting figures and presets are illustrative examples. The washer prices shown are not Cable Glands UK quotations.

Project inputs
RetroSeal costs that still apply

These default to zero in the example scenarios. Enter any permit, testing or production downtime costs your site still requires for the RetroSeal method.

Estimated project saving

—

Calculations appear when the calculator is ready.

Conventional method
—
RetroSeal method
—
Production downtime saved
—
Person-hours saved
—
Net saving per £1 of RetroSeal method cost
—
Estimated project cost breakdown
Cost item Conventional RetroSeal
Fitting / replacement labour — —
Washer supply — —
Re-testing labour — —
Permits / isolation — —
Production downtime — —
Project total — —

Adjust the inputs to compare your project costs.

Ask Cable Glands UK for RetroSeal pricing
How the estimate is calculated
  • Fitting or replacement labour = glands × minutes per gland ÷ 60 × crew size × hourly labour rate.
  • Washer supply = glands × washer unit price. Enter the cost of one washer, rather than one pack.
  • Re-testing = glands × additional testing minutes per cable ÷ 60 × hourly labour rate, using one tester.
  • Permit and isolation costs are counted once per method for the whole project.
  • Production downtime = total affected project hours × downtime cost per hour. It is not multiplied by the number of glands.
  • Each method's total includes labour, washers, testing, permits and production downtime. Saving = conventional total minus RetroSeal total.
  • Person-hours include fitting or replacement and the additional testing labour. Production downtime is calculated separately from labour time.

Keep replacement and testing times separate to avoid counting the same work twice. The example scenarios assume that RetroSeal avoids conventional re-testing, permit and production downtime costs; edit the additional RetroSeal fields when that assumption does not fit your site.

Illustrative estimate based on your inputs. Example fitting times, prices and operating costs are not guaranteed results or confirmed CGUK prices. Site procedures, isolation, inspection and installation requirements still apply. Costs not entered here, including any additional materials or taxes, are excluded.